BITX20A RECEIVER VOLTAGES 

Vsupply = 12.7 volts, Isupply = 127 millamps 

Input terminated in 50 ohms 

Measuring Point 

Voltage 

Cathode D18 

12.40 

Collector Q14/Q13 

11.20 

Emitter Q14 

6.00 

Emitter Q13 

5.90 

Collector Q25 

5.50 

Base Q25 

0.60 

Emitter Q16 

4.85 

Base Q11 

0.65 

Collector Q11 

4.55 

Collector Q17 

10.65 

Emitter Q17 

3.85 

Collector Q9 

8.15 

Base Q9 

2.50 

Emitter Q9 

1.85 

Base Q8 

4.40 

Emitter Q8 

5.60 

Base Q7 

4.30 

Emitter Q7 

3.65 

Collector Q6 

8.50 

Base Q6 

4.10 

Emitter Q6 

3.45 

Collector Q5 

8.15 

Base Q5 

2.50 

Emitter Q5 

1.85